Giỏ hàng đang trống!
Sensing Beam | Visible red Class 1 laser, 655 nm |
---|---|
Supply Voltage (Vcc) | 10 to 30 V dc |
Power and Current Consumption, exclusive of load | < 675 mW |
Sensing Range | 25 mm (0.98 in) to 300 mm (11.81 in) |
Output Configuration | Bipolar (1 PNP & 1 NPN) output |
Output Rating | Off-state leakage current: < 5 μA at 30 V dc PNP On-state saturation voltage: < 1.5 V dc at 100 mA load NPN On-state saturation voltage: < 1.0 V dc at 100 mA load |
Remote Input | Allowable Input Voltage Range: 0 to Vcc Active Low (internal weak pullup—sinking current):Low State < 2.0 V at 1 mA max. |
Supply Protection Circuitry | Protected against reverse polarity, over-voltage, and transient voltages. |
Beam Spot Size | Distance: 25, Size (Horizontal x Vertical) 2.6 mm x 1.0 mm Distance:150, Size (Horizontal x Vertical) 2.3 mm x 0.9 mm Distance:300, Size (Horizontal x Vertical) 2.0 mm x 0.8 mm |
Analog Resolution | 25 mm to 100 mm: < 0.3 mm 100 mm to 300 mm: < 1 mm |
Analog Linearity | Analog linearity performance matches accuracy performance curve (See performance curves in the Instruction Manual - page 23). |
Temperature Effect | 0.05 mm/°C at 125 mm 0.35 mm/°C at 300 mm |
Response Speed | User selectable: 1.5 milliseconds 3 milliseconds 10 milliseconds 25 milliseconds 50 milliseconds Analog models: Total response speed varies from 0.5 ms to 2560 ms, depending on base measurement rate and averaging settings. |
Delay at Power Up | < 750 ms |
Ambient Light Immunity | > 5,000 lux |
Maximum Torque | Side mounting: 1 N·m (9 in·lbs) Nose mounting:20 N·m (177 in·lbs) |
Connector | 5-pin Euro M12 Integral Connector |
Construction | Housing: 316 L stainless steel Lens cover:PMMA acrylic Lightpipe and display window:polysulfone |
Vibration | MIL-STD-202G, Method 201A (10 to 60 Hz, 0.06 in (1.52 mm) double amplitude, 2 hours each along X, Y and Z axes), with sensor operating |
Shock | MIL-STD-202G, Method 213B, Condition I (100G 6x along X, Y and Z axes, 18 total shocks), with sensor operating. |
Environmental Rating | IP67 per IEC60529 IP68 per IEC60529 IP69K per DIN40050-9 |
Chemical Compatibility | Compatible with commonly used acidic or caustic cleaning and disinfecting chemicals used in equipment cleaning and sanitation. Compatible with typical cutting fluids and lubricating fluids used in machining centers. |
Operating Conditions | Temperature: −10 °C to +55 °C (+14 °F to +131 °F) Humidity:35% to 95% relative humidity |
Storage Temperature | –25 °C to +75 °C (−13 °F to +167 °F) |
Application Note | For optimum performance, allow 10 minutes for the sensor to warm up |